Login
About Us
Who we are
Our purpose
Our vision
What we do
Why choose us
Calculators
3-Phase Transformer
3-Phase Motor & 3-Phase Generator
3-Phase Power
Battery,Charger & UPS
LV Cables
LV Max. Demand
Equipment Replacement
Transformer
Motor
Diesel Generator
Batteries
UPS
Predictive Maintenance
Transformer
Motor & Generator
HV Cables
HV Switchboard & Other Equipment
Explanation of Tests
Hazardous Area
Equipment Selection
Ex i Calculation
MDP Calculation
Installation Requirements
HA Classification
Inspection Requirements
EEHA Cloud
Online Ex Dossier
Equipment Health (Coming Soon)
Local Support (Coming Soon)
Contact us
Contact us
Feedback
Sign up
Price & Plans
You need to login to access this equipment replacement module
Login
Create an account
Motor
Parameter
Old (Existing) Motor Details
New Motor Details
Comments
Motor Make
Motor Model
Motor Application
Rated Output (kW)
Rated Voltage (V)
Rated Current (A)
Frequency (Hz)
Select
50
60
Select
50
60
Rated RPM
Power Factor at FL
Efficiency at FL (%)
Net Weight (kg)
Motor Frame
Winding Connection
Select
Star
Delta
Other
Select
Star
Delta
Other
Insulation Class
Select
Class 105°C (A)
Class 130°C (B)
Class 155°C (F)
Class 180°C (H)
Other
Select
Class 105°C (A)
Class 130°C (B)
Class 155°C (F)
Class 180°C (H)
Other
Starting Method
Select
Direct Online (DOL)
Start-Delta
Reactor Starting
Auto-transformer Starting
Rotor Resistance
VSD or VVVF
Other
Select
Direct Online (DOL)
Start-Delta
Reactor Starting
Auto-transformer Starting
Rotor Resistance
VSD or VVVF
Other
Start Current Ratio
Duty Cycle
Select
S1
S2
S3
S4
S5
S6
S7
S8
Select
S1
S2
S3
S4
S5
S6
S7
S8
Service Factor
IP Rating
Motor Internal Temperature Protection
Select
RTD Protection
No Protection
Other
Select
RTD Protection
No Protection
Other
Bearing (DE)
Bearing (NDE)
Noise Level (dBA)
Emergency Stop
Select
Yes
No
Select
Yes
No
Terminal Box Connections
Motor Overall Dimension
Label
×
Motor Duty Cycle General Guideline (Reference IEC 60034-1)
Cycle
Description
Details
S1
Continuous duty
The motor works at a constant load for enough time to reach temperature equilibrium.
S2
Short-time duty
The motor works at a constant load, but not long enough to reach temperature equilibrium. The rest periods are long enough for the motor to reach ambient temperature.
S3
Intermittent periodic duty
Sequential, identical run and rest cycles with constant load. Temperature equilibrium is never reached. Starting current has little effect on temperature rise.
S4
Intermittent periodic duty with starting
Sequential, identical start, run and rest cycles with constant load. Temperature equilibrium is not reached, but starting current affects temperature rise.
S5
Intermittent periodic duty with electric braking
Sequential, identical cycles of starting, running at constant load and running with no load. No rest periods.
S6
Continuous operation with intermittent load
Sequential, identical cycles of running with constant load and running with no load. No rest periods.
S7
Continuous operation with electric braking
Sequential identical cycles of starting, running at constant load and electric braking. No rest periods.
S8
Continuous operation with periodic changes in load and speed
Sequential, identical duty cycles run at constant load and given speed, then run at other constant loads and speeds. No rest periods.
Generating report ...
Terms and Conditions
Privacy Policy
Session Expiring
Your session is about to expire. Would you like to extend it?